Total 220 results | Page 1 of 12
Fire Test

GA ASW 1000

Steel Stud (Non-load-bearing)
Area Seperation Wall
Fire Rating

2 hr.

STC

N/A

Thickness (in.)

3-1/2"

Suitable for attic space.

  • Air Cavity - Min. 3/4 in. thick air space
  • Steel Studs -"H" shaped studs, 2 in. deep by 1-3/8 in. wide, min. 25 ga. spaced max. 24 in
  • Gypsum Board - Two layers of 1 in. thick by nom. 2 ft. wide gypsum liner panels friction fit
  • Air Cavity -Min. 3/4 in. thick air space

Visit U336

Fire Test

GA ASW 2600

Steel Stud (Non-load-bearing)
Area Separation Wall
Fire Rating

3 hr.

STC

N/A

Thickness (in.)

6"

  • Gypsum Board - 1/2 in. thick gypsum board - SHEETROCK Brand Gypsum Panels - 1/2 in.
  • Wood Studs - 2 in. x 4 in. wood studs max. 16 in. OC
  • Batts and Blankets - 3 in. mineral wool batt insulation
  • Air Space - 3/4 in. of air space layer
  • Steel Studs - 2 in. H-Stud 24 in. OC
  • Gypsum Board - Two layers of 1 in. thick by nom. 2 ft. wide gypsum liner panels inserted in shaft wall studs - SHEETROCK Brand Gypsum Liner Panel
  • Air Space - 3/4 in. of air space layer
  • Wood Studs - 2 in. x 4 in. wood studs max. 16 in. OC
  • Batts and Blankets - 3 in. mineral wool batt insulation
  • Gypsum Board - 1/2 in. thick gypsum board - SHEETROCK Brand Gypsum Panels - 1/2 in.

Visit U404

Fire Test

GA-WP-8131

Wood Stud (Load-bearing)
Exterior Walls
Fire Rating

1 hr.

STC

N/A

Thickness (in.)

5-1/8"

  • Cement Board - 1/2 in. or 5/8 in. thick gypsum board, applied horizontally or vertically
  • Sheathing Materials -Min. 15/32 in. thick, 4 ft. wide, wood structural panels, min. grade "sheathing" applied vertically
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC
  • Batts and Blankets -Min. 3 in. thick mineral wool batt insulation
  • Gypsum Board -5/8 in. thick gypsum board applied horizontally or vertically

Visit U303

Fire Test

UL U301

Wood Stud (Load-bearing)
Exterior Walls
Fire Rating

2 hr.

STC

N/A

Thickness (in.)

6"

  • Gypsum Board - 5/8 in. thick gypsum board applied horizontally or vertically
  • Wood Studs -2 in. by 4 in. wood studs spaced max. 16 in. OC
  • Gypsum Board - Two layers of 5/8 in. thick gypsum board applied horizontally

Visit U301

Fire Test

UL U302

Wood Stud (Load-bearing)
Exterior Walls
Fire Rating

2 hr.

STC

N/A

Thickness (in.)

10-3/4"

  • Gypsum Board - Two layers of 5/8 in. thick gypsum board applied horizontally or vertically
  • Wood Studs -2 in. by 4 in. wood studs spaced max. 16 in. OC
  • Gypsum Sheathing (non-rated) -1/2 in. thick gypsum sheathing (non-rated) applied horizontally
  • Corrugated Wall Ties -3/4 in. thick by 6-5/8 in. thick long, 20 MSG galv steel. Attached to each stud with 2-3/8 in. thick long 8d cement coated nails, every sixth course of bricks
  • Clay Face Bricks -2-1/4 in. by 3-3/4 in. by 8 in. with cored holes, laid in full bed of mortar 3/8 to 1/2 in. thick consisting of three parts of clean sharp sand to one part of portland cement (proportioned by vol) and 15 percent hydrated lime (by cement vol)

Visit U302

Fire Test

UL U303

Wood Stud (Load-bearing)
Interior Partitions
Fire Rating

1 hr.

STC

N/A

Thickness (in.)

5-1/8"

  • Cement Board - 1/2 in. thick or 5/8 in. thick cement board applied horizontally or vertically
  • Sheathing Materials -Min 15/32 in. thick, 4 ft. wide, wood structural panels, min. grade "sheathing" applied vertically
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC
  • Batts and Blankets -Min. 3 in. thick mineral wool batt insulation
  • Gypsum Board -5/8 in. thick gypsum board applied horizontally or vertically

Visit U303

Fire Test

UL U305

Wood Stud (Load-bearing)
Interior Partitions
Sound Test: RAL-TL11-172
Fire Rating

1 hr.

STC

33

Thickness (in.)

4-3/4"

  • Gypsum Board - 5/8 in. thick board applied horizontally or vertically
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC
  • Gypsum Board -5/8 in. thick board applied horizontally or vertically

Visit U305

Fire Test

UL U305

Wood Stud (Load-bearing)
Interior Partitions
Sound Test: USG-860807
Fire Rating

1 hr.

STC

37

Thickness (in.)

4-3/4"

  • Gypsum Board - 5/8 in. thick gypsum board applied horizontally or vertically
  • Wood Studs -2 in. x 4 in. wood studs spaced 24 in. OC
  • Gypsum Board -5/8 in. thick gypsum board applied horizontally or vertically

Visit U305

Fire Test

UL U305

Wood Stud (Load-bearing)
Interior Partitions
Sound Test: RAL-TL11-130 / RAL-TL11-173
Fire Rating

1 hr.

STC

34

Thickness (in.)

4-3/4"

  • Gypsum Board - 5/8 in. thick gypsum board applied horizontally or vertically
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC, effectively firestopped
  • Batts and Blankets -Min. 3 in. thick mineral wool batt insulation
  • Gypsum Board -5/8 in. thick gypsum board applied horizontally or vertically

Visit U305

Fire Test

UL U305

Wood Stud (Load-bearing)
Exterior Walls
Fire Rating

1 hr.

STC

N/A

Thickness (in.)

4-3/4"

  • Gypsum Board - 5/8 in. thick gypsum board applied horizontally or vertically
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC, effectively firestopped
  • Gypsum Board -5/8 in. thick, 2 ft. wide gypsum board, tongue and groove edge, applied horizontally to one side of the assembly

Visit U305

Fire Test

UL U305

Wood Stud (Load-bearing)
Interior Partitions
Sound Test: RAL-TL11-129 / RAL-TL15-048
Fire Rating

1 hr.

STC

32

Thickness (in.)

4-3/4"

  • Gypsum Board - 5/8 in. thick gypsum board applied vertically
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC
  • Gypsum Board -5/8 in. thick gypsum board applied vertically

Visit U305

Fire Test

UL U308

Wood Stud (Load-bearing)
Exterior Walls
Fire Rating

2 hr.

STC

N/A

Thickness (in.)

6"

  • Gypsum Board - Two layers of 5/8 in. thick gypsum board applied horizontally or vertically
  • Gypsum Board -5/8 in. thick gypsum board applied horizontally or vertically
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC
  • Batts and Blankets -Min. 3 in. thick mineral wool batt insulation
  • Gypsum Board -5/8 in. thick gypsum board applied horizontally or vertically
  • Cement Board -1/2 in. or 5/8 in. thick gypsum board, applied horizontally or vertically

Visit U308

Fire Test

UL U311

Wood Stud (Load-bearing)
Interior Partitions
Sound Test: SA-830702
Fire Rating

1 hr.

STC

52

Thickness (in.)

5-1/4"

  • Gypsum Board - 5/8 in. thick gypsum board applied horizontally or vertically
  • Resilient Channel -25 ga. furring channels installed horizontally spaced 24 in. OC
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC
  • Batts and Blankets -Min. 3 in. thick mineral wool batts or glass fiber insulation
  • Gypsum Board -5/8 in. thick gypsum board applied horizontally or vertically

Visit U311

Fire Test

UL U314

Wood Stud (Load-bearing)
Interior Partitions
Fire Rating

1 hr.

STC

N/A

Thickness (in.)

4-3/4"

  • Gypsum Board - 5/8 in. thick gypsum board applied horizontally or vertically
  • Wood Studs -2 in. x 4 in. wood studs max. 24 in. OC
  • Gypsum Board -5/8 in. thick gypsum board applied horizontally or vertically

Visit U314

Fire Test

UL U317

Wood Stud (Load-bearing)
Interior Partitions
Fire Rating

0.75 hr.

STC

N/A

Thickness (in.)

4-1/2"

  • Gypsum Board - 1/2 in. thick, 4 ft. board applied horizontally or vertically
  • Wood Studs -2 in. x 4 in. wood stud spaced max. 16 in. OC
  • Gypsum Board -1/2 in. thick gypsum board applied horizontally or vertically

Visit U317

Fire Test

UL U327

Wood Studs
Interior Partitions
Sound Test: RAL-TL11-082
Fire Rating

1 hr.

STC

46

Thickness (in.)

5-1/4"

  • Gypsum Board - 5/8 in. thick gypsum board applied vertically
  • Resilient Channel -25 ga. furring channels installed horizontally spaced 24 in. OC
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC
  • Batts and Blankets -Min. 3-1/2 in. thick fiberglass insulation friction fit in thick stud spaces
  • Gypsum Board -5/8 in. thick gypsum board applied vertically
Fire Test

UL U327

Wood Stud (Load-bearing)
Interior Partitions
Sound Test: RAL-TL11-083
Fire Rating

1 hr.

STC

48

Thickness (in.)

5-1/4"

  • Gypsum Board - 5/8 in. thick gypsum board applied vertically
  • Resilient Channel -25 ga. furring channels installed horizontally spaced 24 in. OC
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC
  • Batts and Blankets -Min. 3-1/2 in. thick fiberglass insulation
  • Gypsum Board -5/8 in. thick gypsum board applied vertically

Visit U327

Fire Test

UL U327

Wood Stud (Load-bearing)
Exterior Walls
Fire Rating

1 hr.

STC

N/A

Thickness (in.)

5-1/4"

  • Gypsum Board - 5/8 in. thick gypsum board applied vertically
  • Resilient Channel -25 ga. furring channels installed horizontally spaced 24 in. OC
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 24 in. OC
  • Batts and Blankets -Min. 3-1/2 in. thick mineral wool batt insulation or 3 in. thick fiberglass insulation
  • Gypsum Board -5/8 in. thick gypsum board applied vertically

Visit U327

Fire Test

UL U329

Wood Stud (Load-bearing)
Exterior Walls
Fire Rating

1 hr.

STC

N/A

Thickness (in.)

4-7/8"

  • Gypsum Board - 5/8 in. thick gypsum sheathing applied horizontally or vertically
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC
  • Batts and Blankets -Min. 3-1/2 in. thick mineral wool batt insulation
  • Cement Board -1/2 in. or 5/8 in. thick board, applied horizontally or vertically
  • Bond Coat for Setting Tile -Latex modified portland cement mortar or .1 type I organic adhesive applied with a notched trowel
  • Ceramic Tile -1/4 in. thick ceramic tile

Visit U329

Fire Test

UL U329 or GA-WP-3441

Wood Stud (Load-bearing)
Interior Partitions
Sound Test: USG-840404
Fire Rating

1 hr.

STC

37

Thickness (in.)

5"

  • Ceramic Tile - 1/4 in. thick ceramic tile
  • Cement Board -1/2 in. thick board, applied horizontally or vertically
  • Wood Studs -2 in. x 4 in. wood studs spaced max. 16 in. OC
  • Batts and Blankets -Min. 3-1/2 in. thick mineral wool batt insulation
  • Cement Board -1/2 in. thick board, applied horizontally or vertically
  • Ceramic Tile -1/4 in. thick ceramic tile

Visit U329

Disclaimer: Most of the published USG sound tests in Design Studio are performed in a laboratory environment. Every detail in the construction of these assemblies is critical in order to achieve the best possible result. When you go from a laboratory to the real world, there are variables that affect the movement of sound that cannot be reproduced in a laboratory. For this reason, we recommend consulting with a local acoustician to insure the highest level of performance for sound transmission.