Quantcast
Total 31 results | Page 1 of 1
Fire Test

L521

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Member - Min. 18 in. (457 mm) deep open web wood truss spaced max. 24 in. (609 mm) OC
  • Foamed Plastic - Max. 10 in. (254 mm) thick spray foam insulation applied to underside of plywood subfloor
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L521

Fire Test

UL G554

Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 3/16 in. (56 mm) thick concrete
  • Steel Deck - Min. 1 5/16 in. (34 mm) deep 24 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 54 in. (1372 mm) OC
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board
Fire Test

UL L521 or GA-FC-5012

Fire Rating

1 hour

STC

63

Assembly Description
  • Floor Covering - Ceramic tile
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L521

Fire Test

UL L521 or GA-FC-5012

Fire Rating

1 hour

STC

63

Assembly Description
  • Floor Covering - Vinyl plank
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L521

Fire Test

UL L521 or GA-FC-5012

Fire Rating

1 hour

STC

63

Assembly Description
  • Floor Covering - Sheet vinyl
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L521

Fire Test

UL L521 or GA-FC-5012

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Min. 12 in. (305 mm) deep open web wood truss spaced max. 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick mineral wool or fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L521

Fire Test

UL L521 or GA-FC-5012

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Min. 12 in. (305 mm) deep open web wood truss spaced max. 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick mineral wool or fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board with 6 in. wide batten strip centered along bottom chord of each truss

Visit UL site for more info on Design L521

Fire Test

UL L521 or GA-FC-5012

Fire Rating

1 hour

STC

63

Featured

Assembly Description
  • Floor Covering - Carpet and pad
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L521

Fire Test

UL L521 or GA-FC-5012

Fire Rating

1 hour

STC

62

Assembly Description
  • Floor Covering - Engineered hardwood
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L521

Fire Test

UL L528 or GA-FC-5515

Fire Rating

1 hour

STC

63

Featured

Assembly Description
  • Floor Covering - Sheet vinyl
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (8 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (457 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L528

Fire Test

UL L528 or GA-FC-5515

Fire Rating

1 hour

STC

N/A

Featured

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Min. 12 in. (305 mm) deep open web wood truss spaced max. 24 in. (609 mm) OC
  • Batts and Blankets - Nom. 3 in. (75 mm) thick mineral wool or nom. 3-1/2 in. (89 mm) fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L528

Fire Test

UL L528 or GA-FC-5515

Fire Rating

1 hour

STC

62

Featured

Assembly Description
  • Floor Covering - Carpet and pad
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (8 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (457 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L528

Fire Test

UL L528 or GA-FC-5515

Fire Rating

1 hour

STC

63

Featured

Assembly Description
  • Floor Covering - Vinyl plank
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (8 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (457 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L528

Fire Test

UL L528 or GA-FC-5515

Fire Rating

1 hour

STC

62

Featured

Assembly Description
  • Floor Covering - Engineered hardwood
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (8 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (457 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L528

Fire Test

UL L528 or GA-FC-5515

Fire Rating

1 hour

STC

63

Featured

Assembly Description
  • Floor Covering - Ceramic tile
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (8 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (457 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L528

Fire Test

UL L529

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Min. 12 in. (305 mm) deep open web wood truss spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. gypsum board

Visit UL site for more info on Design L529

Fire Test

UL L542

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Min. 12 in. (305 mm) deep open web wood truss spaced max. 24 in. (609 mm) OC
  • Finished Ceiling -Two layers 1/2 in. (13 mm) thick gypsum board - null

Visit UL site for more info on Design L542

Fire Test

UL L550 or GA-FC-5012

Sound Test: RAL-0T04-03 & 04
Fire Rating

1 hour

STC

62

Featured

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Min. 12 in. (305 mm) deep open web wood truss spaced max. 24 in. (609 mm) OC
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L550

Fire Test

UL L550 or GA-FC-5012

Sound Test: RAL-0T04-07 & 08
Fire Rating

1 hour

STC

63

Featured

Assembly Description
  • Floor Covering - Sheet vinyl
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L550

Fire Test

UL L550 or GA-FC-5012

Fire Rating

1 hour

STC

63

Featured

Assembly Description
  • Floor Covering - Ceramic tile
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L550

Fire Test

UL L550 or GA-FC-5012

Sound Test: RAL-0T04-11 & 12
Fire Rating

1 hour

STC

63

Featured

Assembly Description
  • Floor Covering - Carpet and pad
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L550

Fire Test

UL L550 or GA-FC-5012

Sound Test: RAL-0T04-05 & 06
Fire Rating

1 hour

STC

62

Featured

Assembly Description
  • Floor Covering - Engineered hardwood
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L550

Fire Test

UL L550 or GA-FC-5012

Sound Test: RAL-0T04-01 & 02
Fire Rating

1 hour

STC

63

Featured

Assembly Description
  • Floor Covering - Vinyl plank
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L550

Fire Test

UL L563 or GA-FC-5012

Sound Test: RAL-TL97-340 & RAL-IN97-47
Fire Rating

1 hour

STC

62

Assembly Description
  • Floor Covering - Engineered hardwood
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L563

Fire Test

UL L563 or GA-FC-5012

Sound Test: RAL-0T04-03 & 04
Fire Rating

1 hour

STC

63

Featured

Assembly Description
  • Floor Covering - Carpet and pad
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L563

Fire Test

UL L563 or GA-FC-5012

Fire Rating

1 hour

STC

63

Assembly Description
  • Floor Covering - Sheet vinyl
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L563

Fire Test

UL L563 or GA-FC-5012

Fire Rating

1 hour

STC

63

Assembly Description
  • Floor Covering - Ceramic tile
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L563

Fire Test

UL L563 or GA-FC-5012

Sound Test: RAL-0T04-11 & 12
Fire Rating

1 hour

STC

63

Assembly Description
  • Floor Covering - Vinyl plank
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (152 mm) thick
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - 18 in. (450 mm) deep open web wood truss spaced 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L563

Fire Test

UL L563 or GA-FC-5012

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Min. 12 in. (305 mm) deep open web wood truss spaced max. 24 in. (609 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick mineral wool or fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L563

Fire Test

UL M521

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Sound Mat (optional) - 3/8 in. (9 mm) thick
  • Floor Substrate - 23/32 in. (18 mm) plywood underlayment OR 3/4 in. structural panel
  • Structural Members - Min. 18 in. (457 mm) deep open web wood truss spaced max. 24 in. (609 mm) OC
  • Batts and Blankets - Min. 3-1/2 in. (89 mm) thick fiberglass insulation
  • Gypsum Board - 5/8 in. (16 mm) thick gypsum board with 6 in. wide batten strip centered along bottom chord of each truss
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board
Fire Test

UL P531 or GA RC 2604

Fire Rating

1 hour

STC

N/A

Featured

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Roof Deck
  • Structural Member - Open web wood truss
  • Ceiling Support - Resilient channels
  • Finished Ceiling - 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P531