Quantcast
Total 10 results | Page 1 of 1
Fire Test

UL L538

Sound Test: RAL-OT03-05/06
Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Min. 9-1/2 in. (241 mm) deep engineered wood I-Joists spaced max. 19.2 in. (488 mm) OC
  • Gypsum Board - 5/8 in. (16 mm) thick gypsum board
  • Ceiling Support - Resilient channels spaced max. 16 in. (406 mm) OC
  • Finished Ceiling -Two layers of 5/8 in. (16 mm) thick gypsum board - null

Visit UL site for more info on Design L538

Fire Test

UL L570 or GA-FC-5011

Sound Test: RAL-0T03-01/02
Fire Rating

1 hour

STC

62

Assembly Description
  • Floor Covering - Cushioned vinyl
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (24 mm) thick
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - 11 7/8 in. (302 mm) deep engineered wood I-Joists spaced 24 in. (609 mm) OC
  • Batts and Blankets - Fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC or suspension system
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L570

Fire Test

UL L570 or GA-FC-5011

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - Min. 9-1/2 in. (241 mm) deep engineered wood I-Joists spaced max. 24 in. (609 mm) OC
  • Batts and Blankets - Fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC or suspension system
  • Finished Ceiling -Two layers of 1/2 in. (13 mm) or 5/8 in. (16 mm) thick gypsum board - null

Visit UL site for more info on Design L570

Fire Test

UL L570 or GA-FC-5011

Fire Rating

1 hour

STC

63

Assembly Description
  • Floor Covering - Vinyl plank
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (24 mm) thick
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - 11 7/8 in. (302 mm) deep engineered wood I-Joists spaced 24 in. (609 mm) OC
  • Batts and Blankets - Fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC or suspension system
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L570

Fire Test

UL L570 or GA-FC-5011

Sound Test: RAL-0T03-05/06
Fire Rating

1 hour

STC

62

Assembly Description
  • Floor Covering - Carpet and pad
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (24 mm) thick
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - 11 7/8 in. (302 mm) deep engineered wood I-Joists spaced 24 in. (609 mm) OC
  • Batts and Blankets - Fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC or suspension system
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L570

Fire Test

UL L570 or GA-FC-5011

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - Min. 9-1/2 in. (241 mm) deep engineered wood I-Joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Resilient channels spaced 24 in. (609 mm) OC or suspension system
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L570

Fire Test

UL L570 or GA-FC-5011

Sound Test: RAL-0T03-05/06
Fire Rating

1 hour

STC

62

Assembly Description
  • Floor Covering - Ceramic tile
  • Floor Underlayment - 1-1/2 in. (38 mm) thick, compressive strength 2500 psi
  • Sound Mat - 3/4 in. (19 mm) thick
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - 11 7/8 in. (302 mm) deep engineered wood I-Joists spaced 24 in. (609 mm) OC
  • Batts and Blankets - Fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC or suspension system
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L570

Fire Test

UL L570 or GA-FC-5011

Fire Rating

1 hour

STC

62

Assembly Description
  • Floor Covering - Engineered hardwood
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 5/16 in. (24 mm) thick
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - 11 7/8 in. (302 mm) deep engineered wood I-Joists spaced 24 in. (609 mm) OC
  • Batts and Blankets - Fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (400 mm) OC or suspension system
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L570

Fire Test

UL M532

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Substrate - 3/4 in. (19 mm) thick concrete structural panel subfloor
  • Structural Members - Min. 9-1/2 in. (241 mm) deep engineered wood I-Joists spaced max. 24 in. (610 mm) OC
  • Batts and Blankets - (Optional) Mineral wool or fiberglass insulation secured to bottom of subfloor
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board with 6 in. wide batten strip centered along bottom chord of each truss
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board
Fire Test

UL M532

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - Min. 9-1/2 in. (241 mm) deep engineered wood I-Joists spaced max. 24 in. (610 mm) OC
  • Batts and Blankets - (Optional) Mineral wool or fiberglass insulation secured to bottom of subfloor
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board with 6 in. wide batten strip centered along bottom chord of each truss
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board