Quantcast
Total 24 results | Page 1 of 1
Fire Test

GA-FC-5120

Fire Rating

1 hour

STC

50-54

Assembly Description
  • Floor Underlayment (optional) - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Floor Substrate - 3/8 in. (9 mm) particle board
  • Subfloor - 5/8 in. (16 mm) plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) 16 in. (406 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) fiberglass insulation
  • Ceiling Support - Furring channels spaced 24 in. (609 mm) OC
  • Finished Ceiling - 1/2 in. (12 mm) thick gypsum board
Fire Test

UL L202

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 20 in. by 60 in. x 3/4 in. [508 x 1524 x 19]
    • Panel Dimensions nom. in. - 20 in. by 60 in. x 5/8 in. [508 x 1524 x 16]
    • Panel Dimensions nom. in. - 24 in. by 60 in. x 3/4 in. [609 x 1524 x 19]
    • Panel Dimensions nom. in. - 24 in. by 60 in. x 5/8 in. [609 x 1524 x 16]

Visit UL site for more info on Design L202

Fire Test

UL L206

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design L206

Fire Test

UL L211

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Ceiling Support - Suspension system
  • Batts and Blankets - 6 in. (152 mm) thick fiberglass insulation
  • Gypsum Board - 1/2 in. (13 mm) thick gypsum board
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design L211

Fire Test

UL L212

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design L212

Fire Test

UL L501

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Gypsum Board - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L501

Fire Test

UL L502

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 1/2 in.(13 mm) or 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L502

Fire Test

UL L508 or GA-FC-5310

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 1-1/8 in. (29 mm) structural wood underlayment
  • Structural Members -Two, Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 48 in. (1219 mm) OC - null
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L508

Fire Test

UL L510

Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 1 in. (25 mm) by 6 in. (150 mm) tongue and groove lumber
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Gypsum Board - 1/2 in. (13 mm) thick gypsum board
  • Ceiling Support - Resilient channels spaced max. 24 in. (610 mm) OC
  • Finished Ceiling - 1/2 in. (13 mm) thick gypsum board

Visit UL site for more info on Design L510

Fire Test

UL L511 or GA-FC-5710

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 1 in. (25 mm) by 6 in. (150 mm) tongue and groove lumber
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Gypsum Board - 5/8 in. (16 mm) thick gypsum board
  • Ceiling Support - Resilient channels spaced max. 24 in. (610 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L511

Fire Test

UL L512

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Gypsum Board - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L512

Fire Test

UL L514

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 1 in. (25 mm) by 6 in. (150 mm) tongue and groove lumber
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Ceiling Support - Resilient channels spaced max. 24 in. (610 mm) OC
  • Finished Ceiling - 1/2 in.(13 mm) or 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L514

Fire Test

UL L515

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 1 in. (25 mm) by 6 in. (150 mm) tongue and groove lumber
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L515

Fire Test

UL L516 or GA-FC-5115

Sound Test: USG-740703
Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Batts and Blankets - 3 in. thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 24 in. (610 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L516

Fire Test

UL L525

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • C Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L525

Fire Test

UL L526

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • C Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L526

Fire Test

UL L541

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Batts and Blankets - Nom. 3 in. (75 mm) thick mineral wool
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling -Two layers of 5/8 in. (16 mm) thick gypsum board - null

Visit UL site for more info on Design L541

Fire Test

UL L569 or GA-FC-5112

Sound Test: RAL-TL04-034 & RAL-IN04-007
Fire Rating

1 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Engineered hardwood
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 3/8 in. (9 mm) thick
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) 16 in. (406 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L569

Fire Test

UL L569 or GA-FC-5112

Fire Rating

1 hour

STC

N/A

Featured

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L569

Fire Test

UL L569 or GA-FC-5112

Fire Rating

1 hour

STC

61

Featured

Assembly Description
  • Floor Covering - Ceramic tile
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 3/8 in. (9 mm) thick
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) 16 in. (406 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L569

Fire Test

UL L569 or GA-FC-5112

Sound Test: RAL-TL04-032 & RAL-IN04-005
Fire Rating

1 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Carpet and pad
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 3/8 in. (9 mm) thick
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) 16 in. (406 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L569

Fire Test

UL L569 or GA-FC-5112

Fire Rating

1 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Sheet vinyl
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 3/8 in. (9 mm) thick
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) 16 in. (406 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L569

Fire Test

UL L569 or GA-FC-5112

Sound Test: RAL-TL04-032 & RAL-IN04-005
Fire Rating

1 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Vinyl plank
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 2500 psi
  • Sound Mat - 3/8 in. (9 mm) thick
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) 16 in. (406 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L569

Fire Test

UL M525

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 19/32 in. (15 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Batts and Blankets - (Optional) Fiberglass insulation secured to bottom of subfloor
  • Gypsum Board - 5/8 in. (16 mm) thick gypsum board