Fire Test

P522

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering - Class A, B or C roof covering
  • Roof Substrate - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Member - Open web wood truss spaced 24 in. (609 mm) OC
  • Foamed Plastic - Max. 10 in. (254 mm) thick spray foam insulation applied to underside of roofing system
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design P522

Fire Test

UL G540

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Steel Open Web Truss - null
  • Floor Substrate - Min. 2 in. (51 mm) thick concrete
  • Structural Members - Light gauge steel truss max. 48 in. (1219 mm) OC
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC when batts and blankets are used
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G540

Fire Test

UL G540

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Steel Open Web Truss - null
  • Floor Substrate - Min. 2 in. (51 mm) thick concrete
  • Structural Members - Light gauge steel truss max. 48 in (1218) OC
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC when batts and blankets are used
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G540

Fire Test

UL L549

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Steel Open Web Truss - null
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Light gauge steel truss max. 48 in. (1218) OC
  • Ceiling Support - Resilient channels 25 ga. spaced 12 in. (305 mm) OC when batts and blankets are used
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L549

Fire Test

UL L551

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Steel Open Web Truss - null
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Light gauge steel truss max. 48 in. (1218) OC
  • Ceiling Support - Suspension system
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L551

Fire Test

UL L551

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Steel Open Web Truss - null
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Light gauge steel truss max. 24 in. (609) OC
  • Ceiling Support - Resilient channels 25 ga. spaced 12 in. (305 mm) OC when batts and blankets are used
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L551

Fire Test

UL L552

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Steel Open Web Truss - null
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Light gauge steel truss max. 48 in. (1218) OC
  • Ceiling Support - Suspension system
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L552

Fire Test

UL L552

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Steel Open Web Truss - null
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Light gauge steel truss max. 24 in. (609) OC
  • Ceiling Support - Resilient channels 25 ga. spaced 12 in. (305 mm) OC when batts and blankets are used
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L552

Fire Test

UL L559

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Gypsum Board - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L559

Fire Test

UL L560

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Steel bar joists spaced max. 48 in. (1219 mm) OC
  • Ceiling Support - Suspension system
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L560

Fire Test

UL L560

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 23/32 in. (18 mm) thick plywood underlayment
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Resilient channels 25 ga. spaced 12 in. (305 mm) OC when batts and blankets are used
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design L560

Fire Test

UL P515

Fire Rating

1 hour

STC

N/A

Featured

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick gypsum board
  • Steel Deck - Corrugated or fluted
  • Structural Member - Steel roof truss
  • Ceiling Support - Hat channels
  • Finished Ceiling - Two layers 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P515

Fire Test

UL P521

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick gypsum board
  • Steel Deck - Corrugated or fluted
  • Structural Member - Steel roof truss
  • Ceiling Support - Resilient channels
  • Finished Ceiling - Two layers of 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P521

Fire Test

UL P521

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick gypsum board
  • Steel Deck - Corrugated or fluted
  • Structural Member - Steel roof truss
  • Ceiling Support - Suspension system
  • Finished Ceiling - Two layers of 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P521

Fire Test

UL P521

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick gypsum board
  • Steel Deck - Corrugated or fluted
  • Structural Member - Steel roof truss
  • Ceiling Support - Suspension system
  • Finished Ceiling - Two layers of 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P521

Fire Test

UL P521

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick gypsum board
  • Steel Deck - Corrugated or fluted
  • Structural Member - Steel roof truss
  • Ceiling Support - Resilient channels
  • Finished Ceiling - Two layers of 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P521

Fire Test

UL P523

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier
  • Steel Deck - Corrugated or fluted
  • Structural Member - Steel roof truss
  • Ceiling Support - Resilient channels
  • Finished Ceiling - 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P523

Fire Test

UL P523

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier
  • Steel Deck - Corrugated or fluted
  • Structural Member - Steel roof truss
  • Ceiling Support - Suspension system
  • Finished Ceiling - Two layers of 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P523

Fire Test

UL P525

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick gypsum board
  • Steel Deck - Corrugated or fluted
  • Structural Member - Light gauge steel roof truss
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P525

Fire Test

UL P525

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick gypsum board
  • Steel Deck - Corrugated or fluted
  • Structural Member - Light gauge steel roof truss
  • Ceiling Support - Resilient channels
  • Finished Ceiling - 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P525

Fire Test

UL P525

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick gypsum board
  • Steel Deck - Corrugated or fluted
  • Structural Member - Light gauge steel roof truss
  • Ceiling Support - Resilient channels
  • Finished Ceiling - Two layers of 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P525

Fire Test

UL P525

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick gypsum board
  • Steel Deck - Corrugated or fluted
  • Structural Member - Light gauge steel roof truss
  • Ceiling Support - Suspension system
  • Finished Ceiling - Two layers of 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P525

Fire Test

UL P526

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Roof Deck
  • Structural Member - Light gauge steel roof truss
  • Ceiling Support - Resilient channels
  • Finished Ceiling - 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P526

Fire Test

UL P527

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier
  • Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. thick board
  • Roof Deck
  • Structural Member - Light gauge steel roof truss
  • Ceiling Support - Resilient channels
  • Finished Ceiling - 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P527

Fire Test

UL P528

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Roof Deck
  • Structural Member - Light gauge steel roof truss
  • Ceiling Support - Resilient channels
  • Finished Ceiling - 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P528

Fire Test

UL P535

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Roof Deck
  • Structural Member - Light gauge steel roof truss
  • Ceiling Support - Resilient channels
  • Finished Ceiling - 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P535