Fire Test

GA-FC-1145

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 in. (51 mm) thick concrete
  • Steel Deck - Min. 25 ga. corrugated steel deck
  • Structural Members - Min. 6 in. (152 mm) deep 18 ga. steel c-joist spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Ceiling - 1/2 in. (13 mm) thick gypsum board
Fire Test

GA-FC-4750

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Underlayment (optional) - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Floor Substrate - 3/4 in. (19 mm) tongue and groove plywood
  • Structural Members - Min. 8 in. (203 mm) deep 18 ga. steel C-Joists max. 24 in. (609 mm) OC
  • Gypsum Board - Three layers of 5/8 in. (16 mm) thick gypsum board
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board
Fire Test

UL G536

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 9-1/4in. (235 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G536

Fire Test

UL G556

Fire Rating

1 hour

STC

N/A

Featured

Assembly Description
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 10 in. (254 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G556

Fire Test

UL G556 or GA-FC-1800

Fire Rating

2 hour

STC

N/A

Featured

Assembly Description
  • Floor Underlayment - Min.1/2 in. (13 mm) thick gypsum-fiber board
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 10 in. (254 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G556

Fire Test

UL G556 or GA-FC-1800

Fire Rating

2 hour

STC

N/A

Featured

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 10 in. (254 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G556

Fire Test

UL G557

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 10 in. (254 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G557

Fire Test

UL G564

Sound Test: RAL-OT05-11 & RAL-OT05-12
Fire Rating

1 hour

STC

63

Featured

Assembly Description
  • Floor Underlayment - Min. 1 in. (25 mm) thick, min. compressive strength 3500 psi
  • Steel Deck - Min. 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - Min. 8 in. (203 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Batts and Blankets - Min. 3-1/2 in. (89 mm) thick mineral wool or fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G564

Fire Test

UL G564

Sound Test: RAL-OT05-09 & RAL-OT05-10
Fire Rating

1 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Vinyl plank
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 3500 psi
  • Sound Mat - 3/8 in. (10 mm) thick
  • Steel Deck - 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - 10 in. (254 mm) deep 16 ga. steel C-Joists 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G564

Fire Test

UL G564

Fire Rating

2 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Engineered hardwood
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 3500 psi
  • Sound Mat - 3/8 in. (10 mm) thick
  • Steel Deck - 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - 10 in. (254 mm) deep 16 ga. steel C-Joists 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G564

Fire Test

UL G564

Sound Test: RAL-OT05-15 & RAL-OT05-16
Fire Rating

1 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Carpet and pad
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 3500 psi
  • Sound Mat - 3/8 in. (10 mm) thick
  • Steel Deck - 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - 10 in. (254 mm) deep 16 ga. steel C-Joists 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G564

Fire Test

UL G564

Fire Rating

1 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Engineered hardwood
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 3500 psi
  • Sound Mat - 3/8 in. (10 mm) thick
  • Steel Deck - 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - 10 in. (254 mm) deep 16 ga. steel C-Joists 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G564

Fire Test

UL G564

Fire Rating

2 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Carpet and pad
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 3500 psi
  • Sound Mat - 3/8 in. (10 mm) thick
  • Steel Deck - 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - 10 in. (254 mm) deep 16 ga. steel C-Joists 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G556

Fire Test

UL G564

Sound Test: RAL-OT05-13 & RAL-OT05-14
Fire Rating

2 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Vinyl plank
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 3500 psi
  • Sound Mat - 3/8 in. (10 mm) thick
  • Steel Deck - 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - 10 in. (254 mm) deep 16 ga. steel C-Joists 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G564

Fire Test

UL G564

Fire Rating

2 hour

STC

N/A

Featured

Assembly Description
  • Floor Underlayment - Min. 1 in. (25 mm) thick, min. compressive strength 3500 psi
  • Steel Deck - Min. 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - Min. 8 in. (203 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Batts and Blankets - Min. 3-1/2 in. (89 mm) thick mineral wool or fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G564

Fire Test

UL H505

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 8 in. (203 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board
Fire Test

UL K506

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Steel Strap - Min. 4 in. wide min 20 ga steel strap
  • Structural Members - Min. 6 in. (152 mm) deep 20 ga. steel c-joist spaced max. 24 in. (609 mm) OC
  • Gypsum Board - Three layers of 5/8 in. (16 mm) thick gypsum board
  • Ceiling Support - Furring channels spaced max. 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design K506

Fire Test

UL L524 or GA-FC-4502

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Min. 7 in. (178 mm) deep 18 ga. (457 mm) steel c-joist spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling -Two layers 1/2 in. (13 mm) thick gypsum board - null

Visit UL site for more info on Design L524

Fire Test

UL L527

Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 3/4 in. (19 mm) thick plywood underlayment
  • Structural Members - Min. 9 3/8 in. (238 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Ceiling Support - Resilient channels spaced 16 in. OC
  • Finished Ceiling - Two layers 5/8 in. gypsum board

Visit UL site for more info on Design L527

Fire Test

UL P518

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick board
  • Steel Deck - Corrugated
  • Structural Member - Steel C-joist
  • Batts and Blankets - Min. 8 in. (203.2 mm) thick fiberglass insulation
  • Ceiling Support - Suspension system
  • Finished Ceiling - Two layers of 1/2 in. (12.7 mm) thick gypsum board

Visit UL site for more info on Design P518

Fire Test

UL P518

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick board
  • Steel Deck - Corrugated
  • Structural Member - Steel C-joist
  • Batts and Blankets - Min. 8 in. (203.2 mm) thick fiberglass insulation
  • Finished Ceiling - Two layers of 1/2 in. (12.7 mm) thick gypsum board

Visit UL site for more info on Design P518