Quantcast
Total 41 results | Page 1 of 2
Fire Test

GA-FC-2030

Sound Test: NGC-4075
Fire Rating

2 hour

STC

53

Assembly Description
  • Floor Substrate - 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Furring channels spaced max. 24 in.(609 mm) OC
  • Ceiling - 1/2 in. (12 mm) thick gypsum board
Fire Test

UL G205

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Steel Bar Joist - null
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel beam min. W6x12, steel bar joists spaced max. 48 in. (1219 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]

Visit UL site for more info on Design G205

Fire Test

UL G211

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 3/16 in. (51 mm) thick concrete
  • Steel Deck - Metal lath
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design G211

Fire Test

UL G262

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 24 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]

Visit UL site for more info on Design G262

Fire Test

UL G264

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 24 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]

Visit UL site for more info on Design G264

Fire Test

UL G267

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 24 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]

Visit UL site for more info on Design G267

Fire Test

UL G502

Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 in. (50 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Finished Ceiling - 1/2 in. (13 mm) thick gypsum board

Visit UL site for more info on Design G502

Fire Test

UL G503

Fire Rating

2 hour

STC

53

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Furring channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G503

Fire Test

UL G512 or GA-FC-3012

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G512

Fire Test

UL G515

Fire Rating

2 hour

STC

54

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Finished Ceiling - 1/2 in. (13 mm) or 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G515

Fire Test

UL G523

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in. (13 mm) or 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G523

Fire Test

UL G523

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 3 in. (76 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G523

Fire Test

UL G524

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in. (13 mm) or 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G524

Fire Test

UL G525

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 3-1/2 in. (89 mm) thick concrete
  • Steel Deck - Min. 1 5/16 in. (34 mm) deep 24 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 48 in. (1219 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G525

Fire Test

UL G529

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in. (13 mm) thick gypsum board

Visit UL site for more info on Design G529

Fire Test

UL G529

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 3/4 in. (70 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G529

Fire Test

UL G529

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 3 1/4 in. (83 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in. (13 mm) thick gypsum board

Visit UL site for more info on Design G529

Fire Test

UL G531

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 3/16 in. (56 mm) thick concrete
  • Steel Deck - Min. 1 5/16 in. (34 mm) deep 24 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in.(13 mm) or 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G531

Fire Test

UL G531

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 3/16 in. (56 mm) thick concrete
  • Steel Deck - Min. 1 5/16 in. (34 mm) deep 24 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G531

Fire Test

UL P201

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. (610 mm x 1219 mm x 19 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 16 mm)

Visit UL site for more info on Design P201

Fire Test

UL P202

Fire Rating

0.75 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. (610 mm x 1219 mm x 19 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 16 mm)

Visit UL site for more info on Design P202

Fire Test

UL P203

Fire Rating

0.75 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier
  • Steel Deck - Min. 7/8 in. (22.23 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. (610 mm x 1219 mm x 19 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 16 mm)

Visit UL site for more info on Design P203

Fire Test

UL P207

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate - Gypsum concrete and gypsum form board
  • Gypsum Concrete - 500 psi
  • Gypsum Form Board - 1 in. (25.4 mm) thick gypsum panels
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. or 3/4 in.
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. or 3/4 in.

Visit UL site for more info on Design P207

Fire Test

UL P214

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. (610 mm x 1219 mm x 19 mm)
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. (610 mm x 610 mm x 16 mm)

Visit UL site for more info on Design P214

Fire Test

UL P225

Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • fire_rating
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.0 psf
  • Steel Deck - Min. 1 in. (25.4 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles

Visit UL site for more info on Design P225

Fire Test

UL P227

Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.0 psf
  • Steel Deck - Min. 1 in. (25.4 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles

Visit UL site for more info on Design P227

Fire Test

UL P229

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Gypsum concrete and gypsum form board
  • Gypsum Concrete - 500 psi
  • Gypsum Form Board - 1 in. (25.4 mm) thick gypsum liner panels
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
  • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. (610 mm x 1219 mm x 19 mm)

Visit UL site for more info on Design P229

Fire Test

UL P230

Fire Rating

1.5 hour

STC

N/A

Featured

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.0 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - USG Paraline® Linear Metal Systems (I, II, III, and PLUS) or acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. (610 mm x 610 mm x 16 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 16 mm) with M7 or MS125 wall angles

Visit UL site for more info on Design P230

Fire Test

UL P230

Fire Rating

1 hour

STC

N/A

Featured

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier (Option 1): Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick gypsum board
  • Thermal Barrier (Option 2): Cement Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick cement board
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - USG Paraline® Linear Metal Systems (I, II, III, and PLUS) or acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. (610 mm x 610 mm x 16 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 16 mm)
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. (610 mm x 610 mm x 19 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. (610 mm x 1219 mm x 19 mm)
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. (610 mm x 610 mm x 19 mm)
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. (610 mm x 610 mm x 16 mm) with M7 or MS125 wall angles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 16 mm) with M7 or MS125 wall angles

Visit UL site for more info on Design P230

Fire Test

UL P235

Fire Rating

1 hour

STC

N/A

Featured

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 1/2 in. (12.7 mm) or 5/8 in. (15.9 mm) thick board
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. (610 mm x 610 mm x 16 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 16 mm)

Visit UL site for more info on Design P235

Fire Test

UL P237

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier
  • Steel Deck - Min. 1 in. (25.4 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Batts and Blankets - 6 in. (152.4 mm) thick fiberglass insulation
  • Gypsum Board - 1/2 in. (12.7 mm) thick gypsum board
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 19 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 16 mm)

Visit UL site for more info on Design P237

Fire Test

UL P244

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate - Gypsum concrete and gypsum form board
  • Gypsum Concrete - 500 psi
  • Gypsum Form Board - 1 in. (25.4 mm) thick gypsum panels
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 16 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1219 mm x 16 mm)

Visit UL site for more info on Design P244

Fire Test

UL P254

Fire Rating

0.75 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick board min. 2.3 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
  • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. (610 mm x 610 mm x 19 mm)

Visit UL site for more info on Design P254

Fire Test

UL P259

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick board 2.0 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles

Visit UL site for more info on Design P259

Fire Test

UL P267

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier
  • Steel Deck - Min. 7/8 in. (22.23 mm) steel roof deck
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - USG Paraline® Linear Metal Systems (I, II, III, and PLUS) (UL Type PAR, PARP, PAS, PASP, PSR, PSRP, PSS, PSSP) or acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. (610 mm x 610 mm x 16 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. (610 mm x 1218 mm x 16 mm)
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. (610 mm x 610 mm x 19 mm)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. (610 mm x 1218 mm x 19 mm)

Visit UL site for more info on Design P267

Fire Test

UL P507

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate - Gypsum concrete and gypsum form board
  • Gypsum Concrete - 500 psi
  • Gypsum Form Board - 1 in. (25.4 mm) thick gypsum panels
  • Structural Member - Steel bar joist
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (15.9 mm) thick gypsum board

Visit UL site for more info on Design P507