Quantcast
Total 18 results | Page 1 of 1
Fire Test

UL D218

Concrete with Steel Floor Units and Beam Support
Panel Sizes: 2x4
Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 3 1/4 in. thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 22 ga. steel deck
  • Structural Members - Steel beam min. W8x15
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles (Type PSS, PSR, PSSP, PSRP)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19] (Optional metal pans to be used with acoustical ceiling)

Visit UL site for more info on Design D218

Fire Test

UL D219

Concrete with Steel Floor Units and Beam Support
Panel Sizes: 2x2, 2x4
Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 3-1/2 in. (89 mm) thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 22 ga. steel deck
  • Structural Members - Steel beam min. W8x15 or steel bar joists
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]

Visit UL site for more info on Design D219

Fire Test

UL G512 or GA-FC-3012

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G512

Fire Test

UL G523

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 3 in. (76 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G523

Fire Test

UL G529

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 3/4 in. (70 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G529

Fire Test

UL G529

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 3 1/4 in. (83 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in. (13 mm) thick gypsum board

Visit UL site for more info on Design G529

Fire Test

UL J504

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Structural Members - 6 in. (152 mm) deep precast concrete
  • Ceiling Support - Furring channels spaced max. 24 in. (610 mm) OC
  • Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design J504

Fire Test

UL J924

Fire Rating

1 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 1/2 in. (13 mm) thick, min. compressive strength 1800 psi
  • Structural Members - 8 in. (203 mm) deep precast concrete

Visit UL site for more info on Design J924

Fire Test

UL J991

Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 1 in. (25 mm) thick, min. compressive strength 1800 psi
  • Structural Members - Min. 8 in. (203 mm) deep precast concrete

Visit UL site for more info on Design J991

Fire Test

UL P713

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.2 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel beam or steel bar joist
  • Spray - Applied fire resistive material (Reference UL design for application requirements)

Visit UL site for more info on Design P713

Fire Test

UL P719

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.2 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel beam or steel bar joist
  • Spray - Applied fire resistive material (Reference UL design for application requirements)

Visit UL site for more info on Design P719

Fire Test

UL P722

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.2 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel beam or steel bar joist
  • Spray - Applied fire resistive material (Reference UL design for application requirements)

Visit UL site for more info on Design P722

Fire Test

UL P727

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.2 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel beam or steel bar joist
  • Spray - Applied fire resistive material (Reference UL design for application requirements)

Visit UL site for more info on Design P727

Fire Test

UL P730

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.2 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel beam or steel bar joist
  • Spray - Applied fire resistive material (Reference UL design for application requirements)

Visit UL site for more info on Design P730

Fire Test

UL P732

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.2 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel beam or steel bar joist
  • Spray - Applied fire resistive material (Reference UL design for application requirements)

Visit UL site for more info on Design P732

Fire Test

UL P733

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.2 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel beam or steel bar joist
  • Spray - Applied fire resistive material (Reference UL design for application requirements)

Visit UL site for more info on Design P733

Fire Test

UL P811

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.0 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel beam
  • Spray - Applied fire resistive material (Reference UL design for application requirements)

Visit UL site for more info on Design P811

Fire Test

UL P826

Fire Rating

3 hour

STC

N/A

Assembly Description
  • Roof Covering
  • Roof Substrate
  • Thermal Barrier: Gypsum Board - 5/8 in. (15.9 mm) thick gypsum board 2.2 psf
  • Steel Deck - Min. 1-1/2 in. (38 mm) steel roof deck
  • Structural Member - Steel beam or steel bar joist
  • Spray - Applied fire resistive material (Reference UL design for application requirements)

Visit UL site for more info on Design P826