Quantcast
Total 65 results | Page 1 of 2
Fire Test

GA-FC-2030

Sound Test: NGC-4075
Fire Rating

2 hour

STC

53

Assembly Description
  • Floor Substrate - 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Furring channels spaced max. 24 in.(609 mm) OC
  • Ceiling - 1/2 in. (12 mm) thick gypsum board
Fire Test

GA-FC-2120

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Structural Members - Precast reinforced concrete
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Ceiling - 5/8 in. (16 mm) thick gypsum board
Fire Test

GA-FC-4750

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Underlayment (optional) - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Floor Substrate - 3/4 in. (19 mm) tongue and groove plywood
  • Structural Members - Min. 8 in. (203 mm) deep 18 ga. steel C-Joists max. 24 in. (609 mm) OC
  • Gypsum Board - Three layers of 5/8 in. (16 mm) thick gypsum board
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board
Fire Test

UL D209

Concrete with Steel Floor Units and Beam Support
Panel Sizes: 2x2, 2x4
Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 20 ga. steel deck
  • Structural Members - Steel beam min. W10x21
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 1219 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design D209

Fire Test

UL D215

Concrete with Steel Floor Units and Beam Support
Panel Sizes: 2x2, 2x4
Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 18 ga. steel deck
  • Structural Members - Steel beam min. W8x15
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]

Visit UL site for more info on Design D215

Fire Test

UL D218

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 22 ga. steel deck
  • Structural Members - Steel beam min. W8x15
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles (TYPE PSS, PSR, PSSP, PSRP, PAS, PAR, PASP, PARP, PIA, PII, PIIIA)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16] (Optional metal pans to be used with acoustical ceiling)

Visit UL site for more info on Design D218

Fire Test

UL D219

Concrete with Steel Floor Units and Beam Support
Panel Sizes: 2x2, 2x4
Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 22 ga. steel deck
  • Structural Members - Steel beam min. W8x15 or steel bar joists
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design D219

Fire Test

UL D501

Fire Rating

1.5 hour

STC

N/A

Featured

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 3 in. (76 mm) deep 22 ga. steel deck
  • Structural Members - Steel beam min. W8x17
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in. gypsum board

Visit UL site for more info on Design D501

Fire Test

UL D502

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 22 ga. steel deck
  • Structural Members - Steel beam min. W8x28
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) gypsum board

Visit UL site for more info on Design D502

Fire Test

UL D503

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 2 in. (51 mm) deep 20 ga. steel deck
  • Structural Members - Steel beam min. W12x19
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) gypsum board

Visit UL site for more info on Design D503

Fire Test

UL G205

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Steel Bar Joist - null
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel beam min. W6x12, steel bar joists spaced max. 48 in. (1219 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]

Visit UL site for more info on Design G205

Fire Test

UL G211

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 3/16 in. (51 mm) thick concrete
  • Steel Deck - Metal lath
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design G211

Fire Test

UL G503

Fire Rating

2 hour

STC

53

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Furring channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G503

Fire Test

UL G515

Fire Rating

2 hour

STC

54

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Finished Ceiling - 1/2 in. (13 mm) or 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G515

Fire Test

UL G523

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in. (13 mm) or 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G523

Fire Test

UL G524

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in. (13 mm) or 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G524

Fire Test

UL G525

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 3-1/2 in. (89 mm) thick concrete
  • Steel Deck - Min. 1 5/16 in. (34 mm) deep 24 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 48 in. (1219 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G525

Fire Test

UL G529

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in. (13 mm) thick gypsum board

Visit UL site for more info on Design G529

Fire Test

UL G531

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 3/16 in. (56 mm) thick concrete
  • Steel Deck - Min. 1 5/16 in. (34 mm) deep 24 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - 1/2 in.(13 mm) or 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G531

Fire Test

UL G536

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 9-1/4in. (235 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G536

Fire Test

UL G540

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Steel Open Web Truss - null
  • Floor Substrate - Min. 2 in. (51 mm) thick concrete
  • Structural Members - Light gauge steel truss max. 48 in (1218) OC
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC when batts and blankets are used
  • Batts and Blankets - Mineral wool or fiberglass insulation
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G540

Fire Test

UL G554

Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 3/16 in. (56 mm) thick concrete
  • Steel Deck - Min. 1 5/16 in. (34 mm) deep 24 ga. corrugated steel deck
  • Structural Members - Steel bar joists spaced max. 54 in. (1372 mm) OC
  • Ceiling Support - Furring channels spaced max. 24 in. (609 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board
Fire Test

UL G556 or GA-FC-1800

Fire Rating

2 hour

STC

N/A

Featured

Assembly Description
  • Floor Underlayment - Min.1/2 in. (13 mm) thick gypsum-fiber board
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 10 in. (254 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G556

Fire Test

UL G556 or GA-FC-1800

Fire Rating

2 hour

STC

N/A

Featured

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 10 in. (254 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G556

Fire Test

UL G557

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 10 in. (254 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - Two layers of 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design G557

Fire Test

UL G564

Fire Rating

2 hour

STC

N/A

Featured

Assembly Description
  • Floor Underlayment - Min. 1 in. (25 mm) thick, min. compressive strength 3500 psi
  • Steel Deck - Min. 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - Min. 8 in. (203 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Batts and Blankets - Min. 3-1/2 in. (89 mm) thick mineral wool or fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G564

Fire Test

UL G564

Sound Test: RAL-OT05-13 & RAL-OT05-14
Fire Rating

2 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Vinyl plank
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 3500 psi
  • Sound Mat - 3/8 in. (10 mm) thick
  • Steel Deck - 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - 10 in. (254 mm) deep 16 ga. steel C-Joists 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G564

Fire Test

UL G564

Fire Rating

2 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Carpet and pad
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 3500 psi
  • Sound Mat - 3/8 in. (10 mm) thick
  • Steel Deck - 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - 10 in. (254 mm) deep 16 ga. steel C-Joists 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G556

Fire Test

UL G564

Fire Rating

2 hour

STC

60

Featured

Assembly Description
  • Floor Covering - Engineered hardwood
  • Floor Underlayment - 1 in. (25 mm) thick, compressive strength 3500 psi
  • Sound Mat - 3/8 in. (10 mm) thick
  • Steel Deck - 9/16 in. (14 mm) deep 22 ga. corrugated steel deck
  • Structural Members - 10 in. (254 mm) deep 16 ga. steel C-Joists 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced 12 in. (305 mm) OC
  • Finished Ceiling - Gypsum board

Visit UL site for more info on Design G564

Fire Test

UL H505

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Concrete structural panel subfloor
  • Structural Members - Min. 8 in. (203 mm) deep 16 ga. steel C-Joists max. 24 in. (610 mm) OC
  • Batts and Blankets - 3-1/2 in. (89 mm) thick fiberglass insulation
  • Ceiling Support - Resilient channels spaced max. 12 in. (305 mm) OC or suspension system
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board
Fire Test

UL J201

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Structural Members - Precast concrete
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]
    • Panel Dimensions nom. in. - 20 in. by 60 in. x 3/4 in. [508 x 1524 x 19]
    • Panel Dimensions nom. in. - 20 in. by 60 in. x 5/8 in. [508 x 1524 x 16]

Visit UL site for more info on Design J201

Fire Test

UL J927

Fire Rating

30 mins.

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Structural Members - Min. 6 in. (152 mm) deep precast concrete

Visit UL site for more info on Design J927

Fire Test

UL J991

Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 1/2 in. (13 mm) thick, min. compressive strength 1800 psi
  • Structural Members - Min. 8 in. (203 mm) deep precast concrete

Visit UL site for more info on Design J991

Fire Test

UL K504

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Ceiling Support - Suspension system
  • Gypsum Board - Three layers of 5/8 in. (16 mm) thick gypsum board
  • Ceiling Support - Furring channels spaced max. 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design K504

Fire Test

UL K506

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Steel Strap - Min. 4 in. wide min 20 ga steel strap
  • Structural Members - Min. 6 in. (152 mm) deep 20 ga. steel c-joist spaced max. 24 in. (609 mm) OC
  • Gypsum Board - Three layers of 5/8 in. (16 mm) thick gypsum board
  • Ceiling Support - Furring channels spaced max. 16 in. (406 mm) OC
  • Finished Ceiling - 5/8 in. (16 mm) thick gypsum board

Visit UL site for more info on Design K506

Fire Test

UL L211

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi
  • Subfloor - 15/32 in. (12 mm) thick plywood underlayment
  • Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC
  • Ceiling Support - Suspension system
  • Batts and Blankets - 6 in. (152 mm) thick fiberglass insulation
  • Gypsum Board - 1/2 in. (13 mm) thick gypsum board
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design L211