Fire Test

UL G205

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Steel Bar Joist - null
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 9/16 in. (14 mm) deep 28 ga. corrugated steel deck
  • Structural Members - Steel beam min. W6x12, steel bar joists spaced max. 48 in. (1219 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]

Visit UL site for more info on Design G205

Fire Test

UL G211

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2 3/16 in. (51 mm) thick concrete
  • Steel Deck - Metal lath
  • Structural Members - Steel bar joists spaced max. 24 in. (609 mm) OC
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design G211