Fire Test

UL D209

Concrete with Steel Floor Units and Beam Support
Panel Sizes: 2x2, 2x4
Fire Rating

1.5 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 20 ga. steel deck
  • Structural Members - Steel beam min. W10x21
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 1219 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design D209

Fire Test

UL D215

Concrete with Steel Floor Units and Beam Support
Panel Sizes: 2x2, 2x4
Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 18 ga. steel deck
  • Structural Members - Steel beam min. W8x15
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]

Visit UL site for more info on Design D215

Fire Test

UL D218

Concrete with Steel Floor Units and Beam Support
Panel Sizes: 2x4
Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 3 1/4 in. thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 22 ga. steel deck
  • Structural Members - Steel beam min. W8x15
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles (Type PSS, PSR, PSSP, PSRP)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19] (Optional metal pans to be used with acoustical ceiling)

Visit UL site for more info on Design D218

Fire Test

UL D218

Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 22 ga. steel deck
  • Structural Members - Steel beam min. W8x15
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles (TYPE PSS, PSR, PSSP, PSRP, PAS, PAR, PASP, PARP, PIA, PII, PIIIA)
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16] (Optional metal pans to be used with acoustical ceiling)

Visit UL site for more info on Design D218

Fire Test

UL D219

Concrete with Steel Floor Units and Beam Support
Panel Sizes: 2x2, 2x4
Fire Rating

3 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 3-1/2 in. (89 mm) thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 22 ga. steel deck
  • Structural Members - Steel beam min. W8x15 or steel bar joists
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]

Visit UL site for more info on Design D219

Fire Test

UL D219

Concrete with Steel Floor Units and Beam Support
Panel Sizes: 2x2, 2x4
Fire Rating

2 hour

STC

N/A

Assembly Description
  • Floor Substrate - Min. 2-1/2 in. (64 mm) thick concrete
  • Steel Deck - Min. 1-1/2 in. (38 mm) deep 22 ga. steel deck
  • Structural Members - Steel beam min. W8x15 or steel bar joists
  • Ceiling Support - Suspension system
  • Finished Ceiling - Acoustical ceiling tiles
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 3/4 in. [609 x 609 x 19]
    • Panel Dimensions nom. in. - 24 in. by 24 in. by 5/8 in. [609 x 609 x 16]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 3/4 in. [609 x 1219 x 19]
    • Panel Dimensions nom. in. - 24 in. by 48 in. by 5/8 in. [609 x 1219 x 16]

Visit UL site for more info on Design D219